Initialization
Protocol Notes
- All communications are in ASCII
- At any time send
‘?’CRto the transmitter for a ASCII list of available commands.- All characters and commands must be upper case
- From the transmitter each field/message is terminated by
CRLF (0x0d 0x0a).- Messages to the transmitter should be terminated with
CRorCRLF.- Any unknown command response is a
‘?’followed by the offending string
Initialization Sequence
- Apply power.
- Issue
RESETcommand, wait for reset. - Verify transmitter initialization is OK, no error issued.
- Issue
NUMP,4command (sets number of transmissions per power level per page). - Verify or set
RestIDvalue, useSTATto verify or issueRID, #command. - Verify PLL is set correctly (initial report should say
USA Frequency).
The transmitter is now ready for normal operation.
Power Up Data
NoteThis data is subject to change at any time. Transmitters will issue a prompt
READYwhen all initializations are complete.
At initial power (POR) application, the unit will transmit the following data:
Data | Description |
|---|---|
|
|
| Indicates the code is checking if this is an initial power up from manufacture or a commanded reset. Certain things will be reconfigured if the memory has been corrupted. |
| Checks passed. |
| Tests and initializes PLL to programmed values. |
| Tests and init complete, errors are reported here. |
| Indicates the ROM PLL values if a |
| Current time of the onboard real time clock. |
Default Status
The following is the default status of the transmitter after entering the STAT command:
NoteAnything below
TheftTimeris subject to change.
STATUS
VER 6.04
RESTID,0
STNID,1
HPWR,3
APGINS,1
NUMP,4
POSPG,0
ALLPAGE, 0
GPEN, 0
VOL,64
AM TRANSMISSION OFF, FF
PLL,37420, 467.7500
RF BAUD = 1200
RIDTIMER = 0
INP, DISABLED
IDLIST = 0 0 0 0
RPTDLY,0
TheftTime=12, TheftTimer=0Updated 18 days ago